<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ELECTRONIC LOAD - EgeRate Elektronik</title>
	<atom:link href="https://www.egerate.com/product-tag/electronic-load/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.egerate.com</link>
	<description></description>
	<lastBuildDate>Fri, 04 Aug 2023 14:39:52 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.egerate.com/wp-content/uploads/2022/03/cropped-logo-2-32x32.png</url>
	<title>ELECTRONIC LOAD - EgeRate Elektronik</title>
	<link>https://www.egerate.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IT-M3800 Series Series Regenerative DC Electronic Load</title>
		<link>https://www.egerate.com/urun/test-ve-olcu/elektriksel-olcum/dc-e-load/it-m3800-seriesseries-regenerative-dc-electronic-load/</link>
		
		<dc:creator><![CDATA[Cihat Çamlıca]]></dc:creator>
		<pubDate>Thu, 29 Sep 2022 07:28:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.egerate.com/?post_type=product&#038;p=5119</guid>

					<description><![CDATA[<p>IT-M3800 series regenerative DC electronic load can not only perform as a DC load, but also feed back power to the grid, which saves electricity and cooling costs for you. It can complete high-precision output and measurement, and supports multiple protection functions. It is well applied to the test of 5G communication and data center, industrial components test, aging test, PV and energy storage test, power optimizer and other fields.</p>
<p>The post <a href="https://www.egerate.com/urun/test-ve-olcu/elektriksel-olcum/dc-e-load/it-m3800-seriesseries-regenerative-dc-electronic-load/"><font color = "#FF0000">IT-M3800 Series </font><br>Series Regenerative DC Electronic Load</a> first appeared on <a href="https://www.egerate.com">EgeRate Elektronik</a>.</p>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<th>Model</th>
<th>Voltage</th>
<th>Current</th>
<th>Power</th>
<th>Resolutıon</th>
<th>Accuracy</th>
<th>Interface</th>
<th>Sıze</th>
</tr>
<tr>
<td>IT-M3802-300-20</td>
<td>300V</td>
<td>20A</td>
<td>2kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3812-80-240</td>
<td>80V</td>
<td>240A</td>
<td>12kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3806-80-120</td>
<td>80V</td>
<td>120A</td>
<td>6kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3804-80-80</td>
<td>80V</td>
<td>80A</td>
<td>4kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3802-80-40</td>
<td>80V</td>
<td>40A</td>
<td>2kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3812-32-480</td>
<td>32V</td>
<td>480A</td>
<td>12kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3806-32-240</td>
<td>32V</td>
<td>240A</td>
<td>6kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3804-32-160</td>
<td>32V</td>
<td>160A</td>
<td>4kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3802-32-80</td>
<td>32V</td>
<td>80A</td>
<td>2kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3807-10-720</td>
<td>10V</td>
<td>12~720A</td>
<td>120~7200W</td>
<td>0.001V/0.1A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3803-10-360</td>
<td>10V</td>
<td>6~360A</td>
<td>60~3600W</td>
<td>0.001V/0.1A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3802-10-240</td>
<td>10V</td>
<td>4~240A</td>
<td>40~2400W</td>
<td>0.001V/0.1A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3801-10-120</td>
<td>10V</td>
<td>3~120A</td>
<td>12~1200W</td>
<td>0.001V/0.1A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3812-1500-24</td>
<td>1500V</td>
<td>24A</td>
<td>12kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3806-1500-12</td>
<td>1500V</td>
<td>12A</td>
<td>6kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3812-800-48</td>
<td>800V</td>
<td>48A</td>
<td>12kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3806-800-24</td>
<td>800V</td>
<td>24A</td>
<td>6kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3804-800-16</td>
<td>800V</td>
<td>16A</td>
<td>4kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3802-800-8</td>
<td>800V</td>
<td>8A</td>
<td>2kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3812-500-72</td>
<td>500V</td>
<td>72A</td>
<td>12kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3806-500-36</td>
<td>500V</td>
<td>36A</td>
<td>6kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3804-500-24</td>
<td>500V</td>
<td>24A</td>
<td>4kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3802-500-12</td>
<td>500V</td>
<td>12A</td>
<td>2kW</td>
<td>0.01V/0.001A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3812-300-120</td>
<td>300V</td>
<td>120A</td>
<td>12kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>2 U</td>
</tr>
<tr>
<td>IT-M3806-300-60</td>
<td>300V</td>
<td>60A</td>
<td>6kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
<tr>
<td>IT-M3804-300-40</td>
<td>300V</td>
<td>40A</td>
<td>4kW</td>
<td>0.001V/0.01A</td>
<td>≤0.03% + 0.03%FS / ≤0.1% + 0.1%FS</td>
<td>USB/CAN/LAN/digital I/O port, optional GPIB/analog &amp; RS232</td>
<td>1 U</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="Pbox3">
<div class="product_info_floor3 product_info_floor33">
<div class="container">
<h2 class="product_info_ptitle">Product Features</h2>
<div class="i"></div>
<div class="product_info_floor3_lr">♦ Compact design, 1U@6kW, 2U@12kW<br />
♦ Voltage range: 10~1500V<br />
♦ Current range: 8A~720A<br />
♦ Power range: 12kW<br />
♦ Master/slave parallel connection with parallel technology &#8211; keep good performance while power extension*1<br />
♦ Efficient power regeneration &#8211;  reduce cost of electricity and cooling<br />
♦ Slope of voltage, current and power is settable<br />
♦ Battery discharge test<br />
<strong>♦ </strong>Short-circuit simulation<br />
<strong>♦ </strong>List function, max.200 steps<br />
♦ 8 operation modes under Source mode：CC/CV/CW/CP/CC+CV/CV+CR/CR+CC/CC+CV+CW+CR<br />
♦ Von function &#8211; On/Off control<br />
♦ Multiple protection: OVP / ±OCP / ±OPP / OTP /voltage transient drop protection/anti-islanding<br />
♦ Power grid automatic detection<br />
<strong>♦ </strong>Pre-charge to prevent current overshoot<br />
♦ Built-in USB/CAN/LAN/digital IO interfaces, Optional GPIB/Analog&amp;RS232<br />
*If parallel connection &gt; 6 units, pls. contact ITECH for details.</div>
</div>
</div>
</div>
<div class="Pbox4">
<div class="product_info_floor3 product_info_floor44 ">
<div class="container">
<h2 class="product_info_ptitle">Functions and Advantages</h2>
<div class="i"></div>
<div class="product_info_floor3_lr">
<p><strong>High power density, compact size design</strong></p>
<p>ITECH has been adhering to the high power density design to help customers optimize test solutions. IT-M3800 series provide up to 6kW power in 1U chassis, and up to 12kW power in 2U chassis. ITECH entire high power density product line is more complete and comprehensive.</p>
<p><strong>Wide range of output, one unit replaces multiple units</strong></p>
<p>IT-M3800 series, with 25 models, the output voltage ranges from 10V to 1500V, and the maximum output current of single unit can reach 720A. With wide range of output desi。 gn, compared with traditional solid output range, IT-M3800 provide users more voltage and current combinations, making the usage more flexible. A single load can cover a wide range of application needs, andsignificantly reduce the complexity and space occupied by the system.</p>
<p><strong>Power regenerative and eco-friendly</strong></p>
<p>With the power regeneration function, IT-M3800 can feed back up to 95% power instead of consuming it as heat. It not only save your cost of electricity, HVAC<br />
and cooling infrastructure, but also help to reduce carbon emission and impact on the environment. In addition, IT-M3800 has the function of automatic grid detection, which can detect phase voltage and frequency in real time and synchronizes with the grid to make energy regeneration automatic and safe.</p>
<p><strong>Electricity accumulation, high energy saving effect</strong></p>
<p>IT-M3800 uses power electronic conversion technology to recycle the output energy of the power supply under test under the premise of completing the test power experiment. Through the internal high-speed voltage and current sampling, the user can directly view the current total amount of feedback on the instrument panel, including voltage/frequency/power of each phase. The total power, real time and historical total recovered electricity. The IT-M3800 series can continue to accumulate electricity on the basis of the value before the last shutdown.</p>
<p><strong>Battery discharge test</strong></p>
<p>The IT-M3800 series have discharge test function, which is suitable for discharging tests on various portable batteries. Three test cut-off conditions of the battery can be set by yourself: cut-off voltage, cut-off capacity and discharge time. When any one of the three conditions is met, the test will be automatically interrupted. During the test, the battery voltage, discharge time and discharged capacity can be observed.</p>
<p><strong>Parallel function</strong></p>
<p>To be convenient and flexible, IT-M3800 uses the master/slave control mode to connect multiple e-loads in parallel to realize high-power testing requirements. Meanwhile, it adopts ITECH&#8217;s optical fiber parallel technology to solve the problems of slow speed and poor accuracy in the traditional parallel mode, suitable for calibration measurement, research and development lab, production line and ATE test setup.</p>
</div>
</div>
</div>
</div>
<div class="Pbox5">
<div class="product_info_floor5">
<div class="container">
<div class="product_info_ptitle">
<p>Options &amp; Accessories</p>
<div class="i"></div>
</div>
<div class="Product_bottom_list">
<ul class="ul">
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2019/06/20190625125103513.jpg" alt="" />
<div class="h3">AC power cord (accessory)</div>
<div class="p1">AC power cord (accessory)</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/IT-E177.jpg" alt="" />
<div class="h3">IT-E177 (accessory)</div>
<div class="p1">RS232/Analog communication car&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201812171139113911.jpg" alt="" />
<div class="h3">USB straight wire (accessory)</div>
<div class="p1">Used for USB port communicatio&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/FCS.jpg" alt="" />
<div class="h3">FCS3000 (Optional)</div>
<div class="p1">Single channel fuel cell simul&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/IT-E176.jpg" alt="" />
<div class="h3">IT-E176 (accessory)</div>
<div class="p1">GPIB communication card</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/bss.jpg" alt="" />
<div class="h3">BSS2000 (Optional)</div>
<div class="p1">Battery simulation software ba&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201812171155435543.jpg" alt="" />
<div class="h3">SAS1000 (Optional)</div>
<div class="p1">Solar array simulation softwar&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/IT-E168.jpg" alt="" />
<div class="h3">IT-E168/169 (Optional)</div>
<div class="p1">Parallel fiber Suite Single ma&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/%E6%9C%BA%E6%9F%9C.jpg" alt="" />
<div class="h3">IT cabinet (Optional)</div>
<div class="p1">IT cabinet 15U/27U/37U</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2021/08/165A.jpg" alt="" />
<div class="h3">IT-E165A-250/400/500 (Optional&#8230;</div>
<div class="p1">Anti-reverse connection module&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2019/06/20190625125103513.jpg" alt="" />
<div class="h3">AC power cord(Optional)</div>
<div class="p1">AC power cord, 5m</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/2018121712080686.jpg" alt="" />
<div class="h3">IT-E30110-AB (Optional)</div>
<div class="p1">10A/1m/crocodile clip &#8211; Banana&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/20190124101604164.jpg" alt="" />
<div class="h3">IT-E30110-BB (Optional)</div>
<div class="p1">10A/1m/ banana plug &#8211; Banana p&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241016221622.jpg" alt="" />
<div class="h3">IT-E30320-YY (Optional)</div>
<div class="p1">30A/ 2M /Y terminals a pair &#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241055195519.jpg" alt="" />
<div class="h3">IT-E30110-BY (Optional)</div>
<div class="p1">10A/1m/ banana plug -Y termina&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E30615-OO (Optional)</div>
<div class="p1">60A/1.5m/ round terminal a p&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241016221622.jpg" alt="" />
<div class="h3">IT-E30312-YY (Optional)</div>
<div class="p1">30A/1.2m/Y terminals a pair &#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E32410-OO (Optional)</div>
<div class="p1">240A/1m/ round terminal a pa&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E31220-OO (Optional)</div>
<div class="p1">120A/2m/ round terminal one &#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E33620-OO (Optional)</div>
<div class="p1">360A/2m/ round terminal a pa&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E32420-OO (Optional)</div>
<div class="p1">240A/2m/ round terminal one &#8230;</div>
</li>
</ul>
<div class="clear"></div>
</div>
</div>
</div>
</div>
<div class="Pbox6">
<div class="product_info_floor6">
<div class="container"></div>
</div>
</div><p>The post <a href="https://www.egerate.com/urun/test-ve-olcu/elektriksel-olcum/dc-e-load/it-m3800-seriesseries-regenerative-dc-electronic-load/"><font color = "#FF0000">IT-M3800 Series </font><br>Series Regenerative DC Electronic Load</a> first appeared on <a href="https://www.egerate.com">EgeRate Elektronik</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IT8400 Series High Performance DC Electronic Load</title>
		<link>https://www.egerate.com/urun/test-ve-olcu/elektriksel-olcum/dc-e-load/it8400-serieshigh-performance-dc-electronic-load/</link>
		
		<dc:creator><![CDATA[Cihat Çamlıca]]></dc:creator>
		<pubDate>Thu, 29 Sep 2022 07:12:15 +0000</pubDate>
				<guid isPermaLink="false">https://www.egerate.com/?post_type=product&#038;p=5115</guid>

					<description><![CDATA[<p>IT8400 high-performance DC electronic load has two voltage levels, 600V and 1200V. It supports master-slave connection in parallel with power from 6 kW to 600 kW, and is capable of fast double power loading. It has three current readback ranges with a resolution of up to 40uA. IT8400 has faster loop response and current rising and falling speed. It supports up to 8 working modes. It also has dynamic mode, List, OCP, OPP test, automatic test and battery test functions. IT8400 has built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, suitable for remote control and system building. In addition, the full protection function makes it well matched with the test of fuel cell, power battery discharge, DC charging pile, BOC, power electronics, solar, automotive high-voltage components, DC-DC, motor and so on.</p>
<p>The post <a href="https://www.egerate.com/urun/test-ve-olcu/elektriksel-olcum/dc-e-load/it8400-serieshigh-performance-dc-electronic-load/"><font color = "#FF0000">IT8400 Series </font><br>High Performance DC Electronic Load</a> first appeared on <a href="https://www.egerate.com">EgeRate Elektronik</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td><strong>MODEL</strong></td>
<td><strong>VOLTAGE</strong></td>
<td><strong>CURRENT</strong></td>
<td><strong>POWER</strong></td>
<td><strong>RESOLUTION</strong></td>
<td><strong>ACCURACY</strong></td>
<td><strong>INTERFACE</strong></td>
<td><strong>SIZE</strong></td>
</tr>
<tr>
<td>IT8430-600-750</td>
<td>600 V</td>
<td>750 A</td>
<td>30 kW</td>
<td>1 mV/ 0.5 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>27 U</td>
</tr>
<tr>
<td>IT8424-1200-300</td>
<td>1200 V</td>
<td>300 A</td>
<td>24 kW</td>
<td>10 mV/ 160 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>27 U</td>
</tr>
<tr>
<td>IT8424-600-600</td>
<td>600 V</td>
<td>600 A</td>
<td>24 kW</td>
<td>1 mV/ 0.4 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>27 U</td>
</tr>
<tr>
<td>IT8418-1200-225</td>
<td>1200 V</td>
<td>225 A</td>
<td>18 kW</td>
<td>10 mV/ 120 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>15 U</td>
</tr>
<tr>
<td>IT8418-600-450</td>
<td>600 V</td>
<td>450 A</td>
<td>18 kW</td>
<td>1 mV/ 0.3 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>15 U</td>
</tr>
<tr>
<td>IT8412-1200-150</td>
<td>1200 V</td>
<td>150 A</td>
<td>12 kW</td>
<td>10 mV/ 80 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>8 U</td>
</tr>
<tr>
<td>IT8412-600-300</td>
<td>600 V</td>
<td>300 A</td>
<td>12 kW</td>
<td>1 mV/ 0.2 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>8 U</td>
</tr>
<tr>
<td>IT8406-1200-75</td>
<td>1200 V</td>
<td>75 A</td>
<td>6 kW</td>
<td>10 mV/ 40 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>4 U</td>
</tr>
<tr>
<td>IT8406-600-150</td>
<td>600 V</td>
<td>150 A</td>
<td>6 kW</td>
<td>1 mV/ 0.1 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>4 U</td>
</tr>
<tr>
<td>IT8454-1200-675</td>
<td>1200 V</td>
<td>675 A</td>
<td>54 kW</td>
<td>10 mV/ 360 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>37 U</td>
</tr>
<tr>
<td>IT8454-600-1350</td>
<td>600 V</td>
<td>1350 A</td>
<td>54 kW</td>
<td>1 mV/ 0.9 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>37 U</td>
</tr>
<tr>
<td>IT8448-1200-600</td>
<td>1200 V</td>
<td>600 A</td>
<td>48 kW</td>
<td>10mV/ 320 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>37 U</td>
</tr>
<tr>
<td>IT8448-600-1200</td>
<td>600 V</td>
<td>1200 A</td>
<td>48 kW</td>
<td>1 mV/ 0.8 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>37 U</td>
</tr>
<tr>
<td>IT8442-1200-525</td>
<td>1200 V</td>
<td>525 A</td>
<td>42 kW</td>
<td>10 mV/ 280 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>37 U</td>
</tr>
<tr>
<td>IT8442-600-1050</td>
<td>600 V</td>
<td>1050 A</td>
<td>42 kW</td>
<td>1 mV/ 0.7 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>37 U</td>
</tr>
<tr>
<td>IT8436-1200-450</td>
<td>1200 V</td>
<td>450 A</td>
<td>36 kW</td>
<td>10 mV/ 240 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>27 U</td>
</tr>
<tr>
<td>IT8436-600-900</td>
<td>600 V</td>
<td>900 A</td>
<td>36 kW</td>
<td>1 mV/ 0.6 mA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>27 U</td>
</tr>
<tr>
<td>IT8430-1200-375</td>
<td>1200 V</td>
<td>375 A</td>
<td>30 kW</td>
<td>10 mV/ 200 μA</td>
<td>±(0.05%+0.05%FS)/ ±(0.05%+0.1%FS)</td>
<td>Built-in LAN/ USB/ RS232/ GPIB/ CAN/ external analog control interface</td>
<td>27 U</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="Pbox3">
<div class="product_info_floor3 product_info_floor33">
<div class="container">
<h2 class="product_info_ptitle">Product Features</h2>
<div class="i"></div>
<div class="product_info_floor3_lr">♦ Max.Voltage : 1200V<br />
♦ Current range: 1.5A~15,000 A<br />
♦ Power extended to 600 kW through master-slave connection in parallel<br />
♦ High-precision three current measurement ranges with resolution up to 40uA<br />
♦ Fast double power loading capability (&lt;3 s)<br />
♦ 25kHz fast dynamic mode, current rising and falling time is adjustable<br />
♦ Provide 8 working modes: CC, CV, CR, CP, CC+CV, CV+CR,CR+CC, CP+CC<br />
♦ 1 kHz continuous sampling rate<br />
♦ List programming<br />
♦ The battery discharge function is used to test energy storage devices such as batteries and super capacitors<br />
♦ CV loop speed is adjustable to match different power supplies<br />
♦ 500 kHz voltage and current sampling rate<br />
♦ Time measurement, OCP/OPP test short circuit simulation, automatic test<br />
♦ Soft start and soft shutdown to prevent voltage fluctuations during on/off<br />
♦ I-monitor function<br />
♦ Full protection: OVP, UVP, OCP, OPP, OTP, current oscillation protection, current limit, power limit, reverse alarm, etc.<br />
♦ Power-off retention memory function, recording up to 100 groups data<br />
♦ Independent control, easy to maintain and install.<br />
♦ Built-in standard LAN, USB, RS232, GPIB, CAN and analog, IO interface<br />
♦ LabVIEW driver and SCPI protocol</div>
</div>
</div>
</div>
<div class="Pbox4">
<div class="product_info_floor3 product_info_floor44 ">
<div class="container">
<h2 class="product_info_ptitle">Functions and Advantages</h2>
<div class="i"></div>
<div class="product_info_floor3_lr">
<p><img decoding="async" src="https://www.itechate.com/uploadfiles/2022/05/20220510161506156.png" alt="" /></p>
<p><strong>Fast loading with double power</strong></p>
<p>The input voltage of IT8400 DC electronic load can reach 1200V. It has a fast double power loading capacity and is available for all models from 6kW to 600kW. You do not need to select the model according to the maximum power during the actual test, which can greatly save your costs. The input over power and loading time are relevant with the temperature of the electronic load. For example: below 30℃, IT8400 supports double power loading within 3 seconds. This makes it suitable for instantaneous high-power discharge tests of motors and batteries. For example, simulating the starting of a DC motor, simulating the transient overload characteristics of some power supplies, or instantaneously discharging a high-power battery or fuel cell.</p>
<p><strong>Higher current rise and fall speed and dynamic speed</strong></p>
<p>Dynamic testing is one of the necessary test items for power supplies. The dynamic mode of IT8400 DC Electronic Load can be used to measure it.Set the current level, time, rising and falling slope and repeat times, and then you can check if the power supply still works stably when the load current is changed stepwise. IT8400 DC Electronic Load supports the programmable dynamic loading mode with 25kHz. The minimum current rise and fall time is 15us. When the loading current changes continuously, the internal monitoring and circuit can minimize the current waveform distortion. So it is well used for transient response test of switching power supply and dynamic discharge test of battery.</p>
<p><strong>3 Current measurement range</strong></p>
<p>All models of IT8400 series DC Electronic Load have 3 current measurement ranges. For example, the 1200V, 6kW model, its current can reach 1.5A. In addition, the high resolution (40uA at most ) and high accuracy (1.5mA at most ) enable it to be widely used in the tests such as solar, power semiconductor devices, automotive electronics and so on.</p>
</div>
</div>
</div>
</div>
<div class="Pbox5">
<div class="product_info_floor5">
<div class="container">
<div class="product_info_ptitle">
<p>Options &amp; Accessories</p>
<div class="i"></div>
</div>
<div class="Product_bottom_list">
<ul class="ul">
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E31220-OO (Optional)</div>
<div class="p1">120A/2m/ round terminal one &#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E33620-OO (Optional)</div>
<div class="p1">360A/2m/ round terminal a pa&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E32420-OO (Optional)</div>
<div class="p1">240A/2m/ round terminal one &#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201901241054585458.jpg" alt="" />
<div class="h3">IT-E32410-OO (Optional)</div>
<div class="p1">240A/1m/ round terminal a pa&#8230;</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/2019/06/20190625125103513.jpg" alt="" />
<div class="h3">AC power cord (accessory)</div>
<div class="p1">AC power cord (accessory)</div>
</li>
<li><img decoding="async" src="https://usa.itechate.com/uploadfiles/%E9%80%89%E9%85%8D%E4%BB%B6/201812171139113911.jpg" alt="" />
<div class="h3">USB straight wire (accessory)</div>
<div class="p1">Used for USB port communicatio&#8230;</div>
</li>
</ul>
<div class="clear"></div>
</div>
</div>
</div>
</div>
<div class="Pbox6">
<div class="product_info_floor6">
<div class="container"></div>
</div>
</div><p>The post <a href="https://www.egerate.com/urun/test-ve-olcu/elektriksel-olcum/dc-e-load/it8400-serieshigh-performance-dc-electronic-load/"><font color = "#FF0000">IT8400 Series </font><br>High Performance DC Electronic Load</a> first appeared on <a href="https://www.egerate.com">EgeRate Elektronik</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
