İçeriğe atla
EgeRate ElektronikEgeRate Elektronik
  • Ana Sayfa
  • Markalar
  • ProAV
  • Test-Ölçüm
  • Mekanik
  • İletişim
Ana Sayfa / Test ve Ölçü / Gelişmiş Ölçüm / RF Güç Ölçüm Cihazı

Average & CW Power Sensors

Kategoriler
  • Mekanik (745)
  • PRO-AV (1140)
  • Test ve Ölçü (971)
    • Çevresel Ölçüm (244)
    • Elektriksel Ölçüm (269)
    • Fiber Optik Ölçüm (4)
    • Gelişmiş Ölçüm (478)
      • Antenler (101)
      • Boroskop (4)
      • Data Logger (Veri Kayıt Cihazı) (27)
      • Daughterboard & USRP (58)
      • Lan Kablo Ölçüm Cihazı (7)
      • Osiloskop (21)
      • Patern Jeneratörü (2)
      • Radyasyon Ölçüm Cihazı (2)
      • RF Güç Ölçüm Cihazı (13)
      • Sinyal Jeneratörü (59)
      • Spectroradiometer (12)
      • Spektrum Analizörü (165)
      • Vektör Network Analizörü (2)
      • Yüksek Hızlı Kamera (7)
  • DESCRIPTION
  • DOWNLOADS
Model Frequency Range Dynamic Range1 Overload Rating Maximum SWR
Impedance
Connector
Pulse/Continuous Frequency SWR @ 0 dBm
Wide dynamic range dual diode sensors
51075A
50 ohm
N (M)
500 kHz to 18 GHz -70 to +20 dBm1 1 W for 1µs
300 mW
500 kHz – 2 GHz
2 GHz – 6 GHz
6 GHz – 18 GHz
1.15
1.20
1.40
51077A
50 ohm
N (M)
500 kHz to 18 GHz -60 to +30 dBm1 10 W for 1µs
3 W
500 kHz – 2 GHz
2 GHz – 6 GHz
6 GHz – 18 GHz
1.15
1.20
1.40
51079A
50 ohm
N (M)
500 kHz to 18 GHz -50 to +40 dBm1 100 W for 1µs
25 W
500 kHz – 2 GHz
2 GHz – 6 GHz
6 GHz – 18 GHz
1.15
1.20
1.40
51071A
50 ohm
K (M)
10 MHz to 26.5 GHz -70 to +20 dBm1 1 W for 1µs
300 mW
10 MHz – 2 GHz
2 GHz – 4 GHz
4 GHz – 18 GHz
18 GHz – 26.5 GHz
1.15
1.20
1.45
1.50
51072A
50 ohm
K (M)
30 MHz to 40 GHz -70 to +20 dBm1 1 W for 1µs
300 mW
30 MHz – 4 GHz
4 GHz – 38 GHz
38 GHz – 40 GHz
1.25
1.65
2.00
Special purpose dual diode sensors
51011A-EMC
50 ohm
N (M)
10 kHz to 8 GHz -60 to +20 dBm2 1 W for 1µs
200 mW
10 MHz – 2 GHz
2 GHz – 4 GHz
4 GHz – 8 GHz
1.12
1.20
1.40
51011A
50 ohm
N (M)
100 kHz to 12.4 GHz -60 to +20 dBm2 1 W for 1µs
300 mW
100 kHz – 2 GHz
2 GHz – 4 GHz
4 GHz – 11 GHz
11 GHz – 12.4 GHz
1.12
1.20
1.40
1.60
Diode Average Sensor (For use with 4530, 5230, 4230, 4240, 4540)
51085
50 ohm
N (M)
500 kHz to 18 GHz -30 to +20 dBm1 15 W for 5 µs

2 W

500 kHz – 4 GHz
4 – 12.4 GHz
12.4 – 18 GHz
1.15
1.20
1.25
51086
50 ohm
K (M)
50 MHz to 26.5 GHz -30 to +20 dBm1 15 W for 5 µs

2 W

500 kHz – 18 GHz

18 – 26.5 GHz

 

1.3

1.35

1 Models: All power meters except 4500B model
2 Models 4240, 4530, 4540

DOWNLOADS

Datasheet

Hızlı Linkler
  • Ana Sayfa
  • PRO-AV
  • Test Ölçü
  • Mekanik
  • İletişim
Kataloglar
  • Gefen
  • Opticis
  • Siglent
  • Itech
  • Mountz
Sosyal
  • Ana Sayfa
  • Markalar
  • ProAV
  • Test-Ölçüm
  • Mekanik
  • İletişim

Giriş Yap